Staging Playground

HomeStaging Playground
 Nexus 1500+Nexus 1450Nexus 1252Nexus 1272Nexus 1262
Typical Application Uses
Utility and Industrial Switchgear – Power Quality MeasurementUtility and Industrial Switchgear – Power Quality MeasurementUtility and Industrial Switchgear – Power Quality MeasurementUtility and Industrial Revenue MeteringUtility and Industrial Revenue Metering
Physical Features
Transducer with Remote Display for Retrofit Installation
Can be installed without cutting Switchboard panel
Display mounts into existing analog meter round knockouts
Power On LED
Display Options
Remote
Color Touchscreen Display
Easy to Read
Up to 10 feet cable length Min for external display
View Waveforms on remote screen
Optical Port / USB Port SharedUSB PortOptical Port/USB (P40N+)
(Optical Port)
High Visibility Multifunction LED display
Front Panel USB connection for direct data download
Ideal for analog ANSI meter retrofits

Meter Features

Basic Measurements and Accuracy
ANSI C12.20 Accuracy Class0.1 class0.1 class0.2 class0.2 class0.2S
0.06% Energy Accuracy0.06
Includes 3 Phase Circuit Parameters
Current Class 2 and Class 20 CombinationClass 20 or 2Class 10 or 2 or 0.5Class 20, 10 or 2Class 20, 10 or 2
Number of Current inputs44433
Wide Band 20 Hz to 500 Hz Frequency
Voltage Range 0-690V Line to Line(5-347) V AC, Line to Neutral
10-600) V AC, Line to Line
(20 to 720) V AC150 V Phase to Neutral, 300 V Phase to Phase (Standard; for use with PTs)
300 V Phase to Neutral, 600 V Phase to Phase (Option G)
Option S: 480 V Max L-N and 600 V L-L
Option LV: 69 V Max L-N and 120 V L-L
Option S: 480 V Max L-N and 600 V L-L
Option LV: 69 V Max L-N and 120 V L-L
Transient Voltage Peak1800 Volts
Current Fault Recording Peak100 A100 A60 A
Overload Conditions 100 A
10 Sec
100 A
10 Sec
100 A
10 Sec
100 A
10 Sec
100 A
10 Sec
Voltage Pickup5V5V2V2V
Current Pick up5 mA/1 mA5 mA/1 mA5 mA/1 mA5 mA/1 mA
Advanced Revenue Measurements
Test Mode
Energy Presets
Transformer and Line Loss compensation
CT & PT Compensation
Time of Use
Accuracy Test Pulse22
(5-S)
Logging
4 GB Memory4 MB4 MBUp to 2 MB
Core Log with 170 automatic parameters4 MB
8 Programmable Historical Logs2 Historical Logs2 Historical Logs2 Historical Logs
Limit Log
I/O Logv
PQ Log
System Events Log
8,000+ Max Stored Waveform Events (before FIFO)
19,000

8,196

95

95
Power Quality
Programmable Alarm Alerts
THD
TDD
K-Factor
Harmonics
(127th Order)

(127th Order)

(255th Order)

(255th Order)

(127th Order)
IEC 61000-4-7 Harmonic Measurements
IEC 61000-4-15 Flicker Measurements
IEC 61000-4-30 Power Quality Class A Edition 3IEC 61000-4-30IEC 61000-4-30
IEEE 1159
IEEE 519
EN50160 PQ ReportingEN50160 PQ AnalysisEN50160 PQ Analysis
Waveform Sampling Rate10241024512512512
kHz Transient Recording
Mhz Transient50 Mhz
CBEMA and SEMI F47 MonitoringITIC/CBEMAITIC/CBEMA
Symmetrical Components and Imbalance (Voltage and Current)
Other
Phasor Measurement UnitP/M
Field Upgrades (V-Switches)
Advanced Web Server with Waveform AnalysisWeb ServerWeb ServerWeb Server
I/O
Digital Inputs
(32-O)(8-S)

(32-O)(8-S)

(32-O)(8-S)

(32-O)(8-S)

(32-O)(8-S)
KYZ Inputs
(32-O)(8-S)

(32-O)(8-S)

(32-O)(8-S)

(32-O)(8-S)

(32-O)(8-S)
Relay Outputs
(28-O)

(16-O)

(16-O)

(16-O)

(16-O)
KYZ Pulse Outputs
(20-O)

(2-S)(16-O)

(16-O)

(16-O)(4-S)

(16-O)(4-S)
Analog Outputs
(32-O)

(32-O)

(32-O)

(32-O)

(32-O)
Analog Inputs
(32-O)

(32-O)

(32-O)

(32-O)

(32-O)
Expand I/O using Modules
Time Synchronization
PTP IEEE 1588
IRIG-B
NTP
Line Frequency Sync
End of Interval Pulse
RTC Clock Accuracy3.5ppm3.5ppm20ppm1 Second per Month1 Second per Month
Cyber Security Features
Password Fail Timeouts Eliminate Brute Force Hacking
Highly Secure Encrypted Passwords - 128 Bit AES Encryption
Firmware upgrade package is encrypted and digitally signed
Role Based Permission access
10 User IDs and Passwords - Up to 30 Characters
Physical security sealing points preventing tampering
Programmable web protocol and port control
Communication
2 Separately Addressable Ethernet Ports using unique IP address
Optional Fiber Optic
6 simultaneously operating communication ports545For INP200 Ethernet card it can connect 12 simultaneous Modbus TCP/IP and up to 5 simultaneous DNP connection, two(2) RS485 connection either Modbus or DNP3.0 + Optical Port and Internal Modem with INP202 Option
Modbus RTU, Modbus ASCII, and Modbus TCP/IP
RTU Master
RTU Gateway
DNP3 Level 2 communication with secure DNP stack
GE EGD
SNMP Traps
Speak SCADA or other communication systems, simultaneously
Emails on Alarm
Standard RS485
(4-S)

(4-S)

(2-S)

(2-S)
Standard RS232
(1-S)

(1-S)
Standard USB on meter base
with P40N+

with P40N+
Standard RJ45 Ethernet
(1-S)

(1-S)

(1-O)

(1-O)
ITIC CBEMA Curve and SEMI F47 ITIC CBEMAITIC CBEMA
MV90 Support
Comtrade Waveforms
IPV6
IPV4 with DHCP
Data Rates1 second, 2 to 20, 1 cycle1 second, 2 to 20, 1 cycle1 cycle, 1 second, 200 ms1 cycle, 1 second, 200 ms100 A
10 Sec
Web Server
HTML5 Interactive Web Server
SEMI F47 and CBEMA Plotting
50160 Report
HTTPS web page
Auto generate SSL certificate
Standards Conformity
UL6010
ANSI C12.20.1 Class 0.10.2S0.2S0.2S
IEC 61557-12
IEC 62053-22 0.2% Energy
IEC 62053-24 0.5% Reactive Energy
IEC61000-4-7
IEC 61000-4-15
IEC 61000-4-30 Class A Edition 3IEC 61000-4-30 IEC 61000-4-30
IEC62586-1 and -2 Test standard for IEC 61000-4-30
IEEE C37.118 - PMU
IEC 60255-5 - Insulation
IEC 60068-2-2 - Environmental Test
Power Supply and Environmental
85 TO 305 V AC or 100 to 140 V DC100–240) V AC
@50/60 Hz or (100-240) V DC
(96-276) V @ 50/60Hz or
DC and (20-500) Hz V AC
120 V AC/DC (-20%) - 230 V AC (+20%)102 to 270 V
AC/DC @50/60 H
102 to 270 V
AC/DC @50/60 H
24 to 48 V DC(18-60) V DC
(24-48 V DC Systems)
(18-60) V DC24 V DC (-20%) - 48 V DC (+20%)(18 to 60) V DC Burden 9 W max(18 to 60) V DC Burden 9 W max
Temperaturenegative 20 to 70 ºCnegative 25 to 70 ºCOperating Temperature: (-40 to +70) °COperating Temperature: (-40 to +85) °C

Display Temperature: (-20 to +60) °C
Operating Temperature: (-40 to +85) °C

Display Temperature: (-20 to +60) °C
Humidity95% Non-condensing95% Non-condensingUp to 95% Non-CondensingUp to 95% Non-CondensingUp to 95% Non-Condensing
Dimensions
0.75" x 4.02" x 4.98" in.3.4 x 7.3 x 10.5 in/8.6 x 18.5 x 26.6 cmSwitchboard: (16.71 cm x 22.86 cm x 22.86 cm)

Socket: 17.68 cm x 15.75 cm
Switchboard: (16.71 cm x 22.86 cm x 22.86 cm)

Socket: 17.68 cm x 15.75 cm
Din Rail Mounted
Display ANSI and DIN 96M mounted
Case DesignPlasticMetalMetalMetal/PlasticMetal/Plastic